kai_bn_img

Na'urar Nazartar Jini Mai Kyau Mai Kyau 3 Sashe na 60 Gwaje-gwaje/Sa'a Analyzer

Auto Hematology Analyzer

· 10.4 Inci tabawa

· 2 hanyoyin kirgawa

· Sake kirgawa ta atomatik

· Lyse a cikin na'urar nazari, babban amfani da sarari

3 Hanyoyin daidaitawa: Manual, Calibrator, Jini

· 6 Harshe


Cikakken Bayani

Tags samfurin

Mun himmatu wajen samar da sauƙi, ceton lokaci da tanadin kuɗaɗen sabis na siyan tasha ɗaya na mabukaci don Ingantaccen Motoci.Hematology Analyzer3 Sashe na 60 Gwaji/Jini na Sa'aAnalyzer, A cikin kalma, lokacin da kuka zaɓe mu, kun zaɓi rayuwa mai kyau.Barka da zuwa ziyarci masana'anta kuma maraba da samun ku!Don ƙarin tambayoyi, ku tuna yawanci kar ku yi shakka don tuntuɓar mu.
Mun himmatu wajen samar da sauƙi, ceton lokaci da tanadin kuɗi na tsayawa tsayin daka na siyan sabis na mabukaci donAnalyzer, Hematology Analyzer, Saboda inganci mai kyau da farashi mai kyau, samfuranmu da mafita an fitar da su zuwa ƙasashe da yankuna fiye da 10.Muna fatan yin haɗin gwiwa tare da duk abokan ciniki daga gida da waje.Bugu da ƙari, gamsuwar abokin ciniki shine biyan mu na har abada.
AerC-3 motaHematology Analyzerkayan aikin gwaji ne na asibiti tare da ayyuka masu wadata da aiki mai sauƙi.Yana iya samar da sigogi 21 da 3 histograms.Ƙididdigar tashoshi biyu.A lokacin tsarin nazarin samfurin, cirewar toshewa ta atomatik da sake ƙidaya ta atomatik yana tabbatar da ingantaccen sakamako na gwaji.An yi amfani da shi sosai a dakunan gwaje-gwaje na asibiti, sassan asibiti da cibiyoyin bincike.

Ma'auni Daidaitawa Ci gaba Tsawon Layi
Rage CV
WBC (7.0-15.0)*109/L ≦2.0% ≦0.5% (0.0-99.9)*109/L
(4.0-6.9)*109/L ≦3.5%
RBC (3.50 ~ 6.5)*109/L ≦1.5% ≦0.5% (0.0-7)*1012/L
HGB (100 ~ 180) g/L ≦1.5% ≦0.5% (0.0 ~ 240) g/L
HGT (70.0 ~ 110.0) fL ≦1.5% / (0.0 ~ 250.0) fL
PLT (150.0 ~ 500.0)*109/L ≦4.0% ≦1% (0.0-999.0)*109/L
(100.0-149.0)*109/L ≦5.0%

1.Abubuwan da suka dace

直方图

  • 21 Siga, 3 Histograms
  • Zaɓin madaidaicin raka'a, akwai yaruka da yawa

2. Ƙararrawar histogram mara kyau

异常报警

  • Idan histogram na sakamakon binciken samfurin ya kasance mara kyau.Na'urar za ta haifar da ƙararrawar histogram ta atomatik.Bayar da R1, R2, R3, R4, Rm, Pm bisa ga nau'in togiya

3.Babban Daidaitawa

双通道技术

  • Ƙididdigar tashoshi biyu, babu gurɓatawa tsakanin tashoshi da ƙarancin ɗaukar nauyi
  • Daidaita wutar lantarki ta atomatik na HGB mara kyau, ta atomatik daidaita madaidaitan ƙararrawa na toshewa da kumfa na buɗe ido.

4.Cost Efficiency

微信图片_20220609152649

  • 2 reagent: Diluent da Lyse
  • Low reagent amfani
  • Gina-in lyse, babban amfani da sarari

5.Sake kirgawa ta atomatik

自动计数

  • Sake kirgawa ta atomatik bayan cire magani yayin da rami ya toshe, a guji sake kirga jini

6.Safety zane

  • Rabewar kewayawa da ruwa, kariyar aminci
  • Kulawa mai dacewa

7.Block-clearing

图层 3

  • Jiƙa a wanke gaba da gaba.real lokaci monitoringmfunction na high matsa lamba kona da kuma atomatik block-shara

Mun himmatu wajen samar da sauƙi, ceton lokaci da tanadin kuɗaɗen sabis na siyan tasha ɗaya na mabukaci don Ingantaccen Tsarin Ciwon Jiki na Auto.Analyzer3 Sashe na 60 Gwaje-gwaje/Sa'a Mai Nazartar Jini, A cikin kalma, lokacin da kuka zaɓe mu, kun zaɓi ingantaccen rayuwa.Barka da zuwa ziyarci masana'anta kuma maraba da samun ku!Don ƙarin tambayoyi, ku tuna yawanci kar ku yi shakka don tuntuɓar mu.
Kyakkyawan Analyzer Hematology Analyzer, Analyzer, Saboda kyawawan inganci da farashi masu kyau, samfuranmu da mafita an fitar dasu zuwa ƙasashe da yankuna sama da 10.Muna fatan yin haɗin gwiwa tare da duk abokan ciniki daga gida da waje.Bugu da ƙari, gamsuwar abokin ciniki shine biyan mu na har abada.


  • Na baya:
  • Na gaba:

  • Tambaya